Thermal Structures Light Product –
Non Seismic
Floor Fire Joint Barriers |
Wall Fire Barriers |
Floor to Wall Fire Barriers |
|||
Fire Joint |
Nominal |
Fire Barrier |
Nominal |
Fire Barrier |
Nominal |
Part Number* |
Joint Width |
Part Number |
Joint Width |
Part Number |
Joint Width |
LFS 5800-F1 |
1 inch |
LFS 5800-W1 |
1 inch |
LFS 5800-FW1 |
1 inch |
LFS 5800-F2 |
2 inches |
LFS 5800-W2 |
2 inches |
LFS 5800-FW2 |
2 inches |
LFS 5800-F3 |
3 inches |
LFS 5800-W3 |
3 inches |
LFS 5800-FW3 |
3 inches |
LFS 5800-F4 |
4 inches |
LFS 5800-W4 |
4 inches |
LFS 5800-FW4 |
4 inches |
LFS 5800-F5 |
5 inches |
LFS 5800-W5 |
5 inches |
LFS 5800-FW5 |
5 inches |
LFS 5800-F6 |
6 inches |
LFS 5800-W6 |
6 inches |
LFS 5800-FW6 |
6 inches |
LFS 5800-F8 |
8 inches |
LFS 5800-W8 |
8 inches |
LFS 5800-FW8 |
8 inches |
LFS 5800-F10 |
10 inches |
LFS 5800-W10 |
10 inches |
LFS 5800-FW10 |
10 inches |
LFS 5800-F12 |
12 inches |
LFS 5800-W12 |
12 inches |
LFS 5800-FW12 |
12 inches |
LFS 5800-F14 |
14 inches |
LFS-5800-W14 |
14 inches |
LFS 5800-FW14 |
14 inches |
LFS 5800-F16 |
16 inches |
LFS 5800-W16 |
16 inches |
LFS 5800-FW16 |
16 inches |
LFS 5800-F18 |
18 inches |
LFS 5800-W18 |
18 inches |
LFS 5800-FW18 |
18 inches |
LFS 5800-F20 |
20 inches |
LFS 5800-W20 |
20 inches |
LFS 5800-FW20 |
20 inches |
Thermal Structures Full Seismic
Product – 50% Expansion, Contraction and Parallel Lateral Shear
Floor Fire Joint Barriers |
Wall Fire Barriers |
Floor to Wall Fire Barriers |
|||
Fire Joint |
Nominal |
Fire Barrier |
Nominal |
Fire Barrier |
Nominal |
Part Number* |
Joint Width |
Part Number |
Joint Width |
Part Number |
Joint Width |
FS 5800-F1 |
1 inch |
FS 5800-W1 |
1 inch |
FS 5800-FW1 |
1 inch |
FS 5800-F2 |
2 inches |
FS 5800-W2 |
2 inches |
FS 5800-FW2 |
2 inches |
FS 5800-F3 |
3 inches |
FS 5800-W3 |
3 inches |
FS 5800-FW3 |
3 inches |
FS 5800-F4 |
4 inches |
FS 5800-W4 |
4 inches |
FS 5800-FW4 |
4 inches |
FS 5800-F5 |
5 inches |
FS 5800-W5 |
5 inches |
FS 5800-FW5 |
5 inches |
FS 5800-F6 |
6 inches |
FS 5800-W6 |
6 inches |
FS 5800-FW6 |
6 inches |
FS 5800-F8 |
8 inches |
FS 5800-W8 |
8 inches |
FS 5800-FW8 |
8 inches |
FS 5800-F10 |
10 inches |
FS 5800-W10 |
10 inches |
FS 5800-FW10 |
10 inches |
FS 5800-F12 |
12 inches |
FS 5800-W12 |
12 inches |
FS 5800-FW12 |
12 inches |
FS 5800-F14 |
14 inches |
FS-5800-W14 |
14 inches |
FS 5800-FW14 |
14 inches |
FS 5800-F16 |
16 inches |
FS 5800-W16 |
16 inches |
FS 5800-FW16 |
16 inches |
FS 5800-F18 |
18 inches |
FS 5800-W18 |
18 inches |
FS 5800-FW18 |
18 inches |
FS 5800-F20 |
20 inches |
FS 5800-W20 |
20 inches |
FS 5800-FW20 |
20 inches |
Both the Light Product and the Full Seismic
Product feature a UL 2 hour fire resistant rating.
*All The Floor barriers are available for coverless chase wall installation. Please call for details
or indicate number of feet needed for chase wall when ordering.
1" to 6" Sizes are sold in 25 foot rolls. Due to product weight constraints, 7" and larger sizes
are sold in 10 foot lengths with flanges pre-welded to the sides.
When ordering fire barrier, allow extra
linear footage for splicing fire barrier together. 1 linear foot of fire
barrier will be lost in the splicing process for every 2 sections of barrier
spliced together.
Number of fire barrier sections to
be spliced |
Total linear feet lost due to
splicing |
2 |
1 |
3 |
2 |
4 |
3 |
5 |
4 |
6 |
5 |
7 |
6 |
8 |
7 |
9 |
8 |
10 |
9 |
US Patent No. 6131352
Canadian Patent No. 2277115
Japanese Patent No. 3188848
Mexican Patent No. 208495