A.
Expansion/Seismic Joint: Refer
to Section 05810 Expansion Joint Assemblies.
B.
Fire Barrier: Expansion Joint Fire Barrier FS 5800 designed for required
structural movement and two-hour fire protection without material
fatigue or degradation.
1.
Sizes available: Floor 1”, 2”, 3”, 4”, 5”, 6”, 8”, 10”,
12”, 14”, 16”, 18”, 20” (Call Manufacturer for additional
sizes) Wall: 1”, 2”,
3”, 4”, 5”,6”,8”,10”,12”,14”,16”,18”,20” (Call
Manufacturer for additional sizes) Floor to Wall:
1”, 2”,
3”,4”,5”,6”,8”,10”,12”,14”,16”,18”,20” (Call
Manufacturer for additional sizes)
C. Accessories: Galvanized flanges are required
for complete installation. No
Fire Caulk needed for installation.
A. In addition to the requirements of these
specifications, comply with manufacturer’s instructions and
recommendations for all phases of work including preparation of
substrate, installation of materials and protection of installed
units.
B. Install fire barrier in conjunction with
expansion joint in accordance with federal, state and local building
coded using manufacturer’s instructions.